To be used under screed for all types of structural concrete floors. Suitable for new build, refurbishments, and conversions.
ResiScreed 6 (6mm thickness) is ideal for projects with minimal height restrictions while still achieving excellent acoustic performance.
By ensuring that all the joints are taped, bridging will be eliminated which is the single greatest cause of failure of any system of this type.
To be used under screed for all types of structural concrete floors. Suitable for new build, refurbishments, and conversions.
ResiScreed 8 (8mm thickness) provides enhanced acoustic performance for standard concrete floor applications.
By ensuring that all the joints are taped, bridging will be eliminated which is the single greatest cause of failure of any system of this type.
To be used under screed for all types of structural concrete floors. Suitable for new build, refurbishments, and conversions.
ResiScreed 10 (10mm thickness) offers maximum acoustic performance for the most demanding acoustic requirements.
By ensuring that all the joints are taped, bridging will be eliminated which is the single greatest cause of failure of any system of this type.
Treated floor with: Isocheck ResiScreed 6
Impact Improvement: 25dB Δ Lw
Tested as a single layer. Composition prevents water transmission which can impair acoustic performance.
- Site results (in red) for Building Control approval.
- Laboratory results (in blue) for comparison.
Treated floor with: Isocheck ResiScreed 8
Impact Improvement: 25dB Δ Lw
Tested as a single layer. Composition prevents water transmission which can impair acoustic performance.
- Site results (in red) for Building Control approval.
- Laboratory results (in blue) for comparison.
Treated floor with: Isocheck ResiScreed 10
Impact Improvement: 25dB Δ Lw
Tested as a single layer. Composition prevents water transmission which can impair acoustic performance.
- Site results (in red) for Building Control approval.
- Laboratory results (in blue) for comparison.
Isocheck ResiScreed 6, supplied by Isomass Ltd. Unit 14 Papworth Business Park, Stirling Way, Papworth Everard, Cambridgeshire CB23 3GY and installed in accordance with manufacturer's instructions / recommendations.
Isocheck ResiScreed 8, supplied by Isomass Ltd. Unit 14 Papworth Business Park, Stirling Way, Papworth Everard, Cambridgeshire CB23 3GY and installed in accordance with manufacturer's instructions / recommendations.
Isocheck ResiScreed 10, supplied by Isomass Ltd. Unit 14 Papworth Business Park, Stirling Way, Papworth Everard, Cambridgeshire CB23 3GY and installed in accordance with manufacturer's instructions / recommendations.
The floor surface should be swept free of any loose debris that may damage or bridge the system.
Butt joint and seal all roll edges of Isocheck ResiScreed 6. At perimeters overlap ResiScreed 6 onto a right angle flanking edge strip which should be turned up all vertical surfaces to allow a minimum 50mm to protrude above the intended FFL of the screed.
Perimeter overlaps or butt joints should be sealed with a min 100mm wide Isocheck jointing tape.
Services that penetrate the screed should be isolated by wrapping with ResiScreed 6 which again would be taped.
When trafficking the floor take care not to perform any unnecessary actions that may cause any of the taped joints to be forced apart.
The floor surface should be swept free of any loose debris that may damage or bridge the system.
Butt joint and seal all roll edges of Isocheck ResiScreed 8. At perimeters overlap ResiScreed 8 onto a right angle flanking edge strip which should be turned up all vertical surfaces to allow a minimum 50mm to protrude above the intended FFL of the screed.
Perimeter overlaps or butt joints should be sealed with a min 100mm wide Isocheck jointing tape.
Services that penetrate the screed should be isolated by wrapping with ResiScreed 8 which again would be taped.
When trafficking the floor take care not to perform any unnecessary actions that may cause any of the taped joints to be forced apart.
The floor surface should be swept free of any loose debris that may damage or bridge the system.
Butt joint and seal all roll edges of Isocheck ResiScreed 10. At perimeters overlap ResiScreed 10 onto a right angle flanking edge strip which should be turned up all vertical surfaces to allow a minimum 50mm to protrude above the intended FFL of the screed.
Perimeter overlaps or butt joints should be sealed with a min 100mm wide Isocheck jointing tape.
Services that penetrate the screed should be isolated by wrapping with ResiScreed 10 which again would be taped.
When trafficking the floor take care not to perform any unnecessary actions that may cause any of the taped joints to be forced apart.
Find Isocheck ResiScreed 6 on NBS Source for detailed specifications and BIM objects.
Find Isocheck ResiScreed 8 on NBS Source for detailed specifications and BIM objects.
Find Isocheck ResiScreed 10 on NBS Source for detailed specifications and BIM objects.